7-day programmable function for energy-saving operation
On/off control output for heating device
Symbol indicator when heating is on
Mechanical switch key for power supply
Temperature limitation function for protecting floor
7-day time maintenance in event of power failure
Large size LCD display for nice readout
Key-lock function for protecting the set parameters (especially suitable for public places)
Specifications:
Voltage: 230V AC (110 or 24V AC available)
Power consumption: 2W
Setting range: 5 to 50°C (factory setting: 5 to 35°C)
Limitation range: 4 to 99°C (factory setting: 28 to 32°C) (except RTC75.33)
Switching differential: ±0.5K
Ambient temperature: -5 to 50°C
Protective housing: IP20
Housing material: self-extinguishing PC
Floor sensor: rubber-thermoplastic NTC sensor,
Cable length: 3m
RTC75.713T 3A built-in floor sensor (optional)
Applications:
2-position control
On/off output for controlling temperature
NTC sensor placed externally or internally
Acquires temperature with built-in sensor or floor sensor
Will close when room temperature falls below selected set point
For control of warm-water (floor) heating systems and direct electric heating systems used in commercial buildings, residential buildings and light industrial buildings